The resistivity of carbon-carbon composites is affected by many factors, including carbon fiber volume fraction, carbon fiber length and carbonization temperature. The experimental results show that the increase in carbon fiber volume fraction will reduce the resistivity of carbon-carbon composites, while the increase in carbon fiber length will increase the resistivity; in addition, the increase in carbonization temperature will also lead to an increase in resistivity.
Measurement method
The main methods for measuring the resistivity of carbon-carbon composites are the double-probe method and the four-probe method. The double-probe method measures the current and voltage values by placing two probes at both ends of the sample to be measured, but this method has a large error when measuring low-resistivity carbon fibers. The four-probe method uses four probes for measurement, two of which are used to pass current and the other two are used to measure voltage. Since the voltage electrode and the current electrode are separated, the influence of contact resistance and lead resistance can be ignored, thereby improving the accuracy of the measurement.